EasyManuals Logo
Home>Pima>Security System>FORCE Series

Pima FORCE Series Installation Guide

Pima FORCE Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
FORCE Series Installation Guide
16 PIMA Electronic Systems
4 Peripherals
The
Peripherals
menu includes the following sub-menus:
1) Zone Expanders: see below.
2) Tampers and EOLs: see below.
3) Keypads: set the no. of addressable keypads (ID=1-16; FORCE Lite/32: ID=1-8). Keypad
with ID=0 is not supervised, nor can it be partitioned.
4) Keypad Settings: see section 4.3, on page 17.
5) Outputs Expanders: set the no. of the relay output expanders.
6) Wireless Peripherals: see section 4.3, on page 17.
4.1 Zone expanders
System Configuration
Peripherals
Zone Expanders
The
Zone Expanders
menu includes the following sub-menus:
1) Remote Zone Exp.: set the no. of 8/16 zone expanders.
Each 16-zone expander is programmed as two 8-zone expanders and
occupies 2 consecutive ID numbers. For example, if expander #3 is a
16-zone one, it takes ID numbers 3 and 4 and so expander #4, the next
expander will take ID number 5 (and not 4).
2) Local Zone Expander: select if the ZEL508 local zone expander is installed.
3) Zone Doubling: when selected the onboard zone 1-8 inputs can be used as inputs for 8
additional zones; see section 2.3.3, on page 12.
4.2 Tampers and EOLs
System Configuration
Peripherals
Tampers and EOLs
Parameter
Description
Tamper 1
TMPR1 input is active.
Tamper 1+EOL
TMPR1 input is EOL supervised, for detecting a short (one EOL).
Tamper 2
TMPR2 input is active. FORCE Lite/32: unavailable
Tamper 2+EOL
TMPR2 input is EOL supervised, for detecting a short (one EOL).
External Siren+EOL
The SIREN Ext./Int. output is EOL supervised, for detecting cut and
short.
Internal Siren+EOL
Double EOL
Two EOL resistors are used on all EOL supervised loops.
Resistor 1-2
Enter the resistors values in Ohm. The value entered is multiplied by
100. For example, when using a 2.2kW resistor, set the value to
220
.

Table of Contents

Other manuals for Pima FORCE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima FORCE Series and is the answer not in the manual?

Pima FORCE Series Specifications

General IconGeneral
BrandPima
ModelFORCE Series
CategorySecurity System
LanguageEnglish

Related product manuals