Appendix C: Programmable Output Types
PIMA Electronic Systems
41
Appendix C. Programmable Output Types
Output Type
Activation
Deactivation
18
Timer
Partitioning
Default
1-9998
(sec)
9999
(Follower)
0
(Latch)
19
Alarms: Burglary, Panic, Silent
panic, Fire, Medical, Duress, Anti-
mask, Custom zone type 1-5
Alarm triggering
Activation time elapses, or
disarming.
240 sec
Faults: Any fault, AC, Low
battery, Phone line/Network,
Cellular modem, Communication,
Tamper
Fault occurrence
9999
External siren
Siren triggered
240 sec
Internal siren
Zone bypass
20
Bypassing a zone
9999
Smoke Reset
Fire zone, or keypad alarm.
Activation time elapses, or
key is pressed and held.
60 sec
Chime Activation
Chime triggered
Activation time elapses
3 sec
Output-Key fob: output activation
by a keyfob
PIMA key fob: press the
Visonic key fob: press
the asterisk (*) key
Activation time elapses, or
key pressed again.


5 sec
Energy saving
All zones are closed
Activation time elapses


15 min
Code keystrokes
Code Keystrokes
counter
exceeds limit
Activation time elapses
21
24 key-
strokes
Operation code 1-8
Entering a code
Activation time elapses
22
5 sec
18
For non-follower timers
19
Latched, until system/partition disarming.
20
See more below the table.
21
Subject to the keypad’s partitioning
22
Toggle mode

Table of Contents

Other manuals for Pima FORCE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima FORCE Series and is the answer not in the manual?

Pima FORCE Series Specifications

General IconGeneral
BrandPima
ModelFORCE Series
CategorySecurity System
LanguageEnglish

Related product manuals