Force Security System - Installation Guide
12
2.8 Connecting sirens
The Sirens inputs are for DC sirens only.
1. Connect the external siren to the SIREN Ext.
terminals
2. Connect the internal siren to the SIREN Int.
terminals
3. For EOL loop supervision, connect a 2K resistor
between the two siren wires, close or inside the
siren’s enclosure.
Figure 9. Sirens connection
2.9 Connecting zones and outputs expanders
PIMA’s product line includes zone and output expanders. All expanders interface with the BUS.
Following is the expanders list:
ZEL508
Local 8-zone expander. The expander is installed beside the control panel and is
connected using a special 4-wire cable.
ZEX508
Remote 8-zone expander with one relay output
ZEX516
Remote 16-zone expander with two relay outputs
OEX508
Remote 8-relay outputs expander
2.9.1 Interfacing with the BUS
Figure 10. Connecting peripherals over the BUS
External
Siren
Internal
Siren
1 2 3 4
ON CEY
POWER SUPPLY
ID
1
+
2 3 4 5 6 7 8
1 )-( 2 )+( 3 4
ForceBus
TAMPER
RELAY1
NC Com NO
BOOT
IntTamper
Disconnect
RUN
BUS
FE
-8
Max. BUS
length: 500m
Keypad
Keypad
Control Panel’s
FORCE BUS Terminals
Expansion Card

Table of Contents

Other manuals for Pima FORCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima FORCE and is the answer not in the manual?

Pima FORCE Specifications

General IconGeneral
BrandPima
ModelFORCE
CategorySecurity System
LanguageEnglish

Related product manuals