Force Security System - Installation Guide
28
Chap. 6 Zones
The
Zones
menu includes the following sub-menus:
1) Zone Settings. See below.
2) Zone Type Settings. See section 6.2, on page 29.
3) Copy Zones. See section 6.3, on page 30.
4) Partitions Names. See section 6.4, on page 30.
6.1 Zone Settings
System Configuration
Zones
Zone Settings
Press * or # to select a zone.
1) Type: select the zone type from the list. See the list below.
2) Name: user text, up to 28 characters.
3) Delay/24H: select from the following options:
Parameter
Description
Instant
Opening this zone while the system is armed will trigger the alarm instantly
Entry Delay #1-2
Opening this zone while the system is armed will trigger the alarm only
after this delay elapses, unless the system is meanwhile disarmed.
Delay Follower
Opening this zone while the system is armed will not trigger the alarm as
long as the entry delay has not expired. If the delay elapses and the zone
is still open, the alarm will be set off.
24 Hour
This zone is constantly armed, regardless of the system state of arming.
In use mostly with smoke detectors and panic keys.
4) Attributes: select from the following list:
Parameter
Description
Disabled
The zone is permanently inactive.
Normally Open
Selected: Normally Open zone
Unselected: Normally Close zone
Allocated to
Home 1-4
Select to which
Home
partial arming mode this zone will be allocated to.
Multiple selection is allowed.
EOL Supervision
Select if the zone will be supervised for cut and/or short
7
.
Chime Zone
This zone will trigger the keypad buzzer, whenever it is opened while
the system is disarmed. Also triggered is the
Chime Activation
programmed output type.
Roller Blinds
Select to adjust the zone’s sensitivity to roller blinds.
5) False Alarms: select from the list that follows (
Inactive
is also an option).
Parameter
Description
Double Knock
This zone will trigger the alarm only if two pulses are detected during
the
Double Knock
time (see Chap. 10, on page 39).
Cross Zoning
This zone will trigger the alarm when opened, only if other cross zone is
opened too, during the
Cross Zoning
time (see Chap. 10, on page 39).
7
Depending on the defined number of resistors. See Chap. 11, on page 42.

Table of Contents

Other manuals for Pima FORCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima FORCE and is the answer not in the manual?

Pima FORCE Specifications

General IconGeneral
BrandPima
ModelFORCE
CategorySecurity System
LanguageEnglish

Related product manuals