Force Security System - Installation Guide
30
Attribute
When selected...
Alarm Re-
triggering
Selected: if the zone is still open at the end of the alarm time, the
zone will retrigger the alarm, continue to activate the sirens and will
generate a new alarm report.
Unselected: if the zone is still open when the alarm time elapses, it
will NOT retrigger the alarm (unless it is closed and re-opened).
This attribute can only be used, if the Trigger Sirens attribute
is selected too.
Activate
Buzzer
The keypad’s buzzer will sound beeps throughout the alarm time
User Bypass
Users are allowed to bypass the zone temporarily (for the next arming
session, or until the
Zone Bypass Limit
time elapses)
6.3 Copy Zones
System Configuration
Zones
Copy Zones
Select between copying a single zone’s attributes, type, partitions, and name to one or more
zones, and copying succeeding zones to a different location.
1) Single to Multiple: see below.
2) Multiple to Multiple: see below.
6.3.1 Single to Multiple
1) Select the zone to be copied and to which zone/s.
2) Copy Options:
Attribute
What will be copied
Zone Attributes
The parameters from the zone attribute screen
Zone Type
The zone type
Zone Partitions
The partitions that the zone is allocated to
Zone Name
The zone name
6.4 Multiple to Multiple
1) Define a group of consecutive zones to be copied.
2) Select a zone from which the zones will be copied to; for example, if you select to copy
zones 21-34 (14 zones) and select zone 47, the 14 zones will be copied to zones 47-60.
3) Copy Options: see above.
6.5 Partitions Names
System Configuration
Zones
Partitions Names
Partitions can have unique names that will appear in the contacts reports and the event memory.
1) Use # or * to scroll and select the partition.
Name: user text, up to 16 characters.

Table of Contents

Other manuals for Pima FORCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima FORCE and is the answer not in the manual?

Pima FORCE Specifications

General IconGeneral
BrandPima
ModelFORCE
CategorySecurity System
LanguageEnglish

Related product manuals