Action and alarm keys
Pressing and holding some keys allows the following actions:
Turn on/off the keypad’s buzzer for all the chime zones
Display the service provider, system name and cloud code
Keypad alarms
The users can trigger three different alarms - panic, fire, and medical - by pressing and holding
key combinations on the keypad. When these alarms are triggered, FORCE activates the
programmed responses for such alarms, including triggering the sirens and reporting the CMS
(where relevant) and contacts.
The same as in
Medical
zone
The same as in
Panic
zone
Keypad settings
Press and hold the keypad settings key to enter the settings
screen. In this screen you set the keypad’s audio visual definitions:
contrast
,
brightness
,
keys backlight
and the buzzer’s
volume
.
Each setting is scaled 0-9. Settings are per keypad.
Use the arrow keys to select a parameter, press Esc to save
and exit.
Warning: if you set the volume to 0, no alert will be sounded from the
keypad buzzer, including from chime zones.
2.12.3 Connect the KLT/KLR500 keypads
Follow the next steps to connect the keypads
:
1. Insert a flathead screwdriver to the notches on the keypad’s
bottom, press and remove the backplate.
2. Pass the BUS wires through the opening at the backplate.
3. Mount the backplate on a flat surface.
4. Connect the BUS wires.
5. Attach the keypad to the mounted backplate, top side first.
The tamper reports over the BUS.