Chap. 4: Installation Wizard
25
Chap. 4 Installation Wizard
Parameter
Description
Default
Range
Time and Date
The system time
-
-
Entry Delay 1
A period of time that should allow disarming and
entering the premises through delayed zones, and
disarming the control panel, without triggering the
alarm.
30 sec
0-250
Exit Delay 1
A period of time that should allow arming and
exiting the premises through delayed zones, without
triggering the alarm.
60 sec
5-250
Ext. Siren
The
External Siren
programmed output type time
240 sec
0-9998
Int. Siren
The
Internal Siren
programmed output type time
Remote Expanders
The no. of remote ZEX508/516 zone expanders.
0
0-16
6
Keypads
The no. of addressable keypads (ID 1-16)
0
1-16
Tech. Code
The Master technician code
-
-
CMS1
See section 8.1, on page 33.
Report Codes
See page 34.
6
Depending on the overall zone number.