17.3T
echnicalspecification—ACU-200,ACU-300,ACU-400
ACU-200A
CU-300ACU-400
Drivecurrentoutput
•Maximum
continuous15A
atsupplyvoltage
.
•Maximum
continuous
5Aat
supplyvoltage.
•Maximum
continuous30A
atsupplyvoltage.
Driveclutchoutput
Upto2.0Acontinuous,
selectablebetween12
/24V
Noclutchconnection.•Upto4Acontinuous
at12Von12V
systems.
•Upto4Acontinuous
at24Von24V
systems.
•Upto4Acontinuous
at12Von24V
systems.
Connections
•Rudderangle
referencesensor
/transducer
.
•Sleep switch.
•Power.
•Drivemotor.
•Driveclutch.
•Ground.
•Rudderangle
referencesensor
/transducer.
•Sleepswitch.
•Power.
•Solenoiddriveout/
return.
•Ground.
•Rudderangle
referencesensor
/transducer.
•Sleepswitch.
•Power.
•Drivemotor.
•Driveclutch.
•Ground.
•DigitalInput/Output
(DIO).
Nominalsupply
voltage
12Vor24V
Operatingvoltage
range
10.8V to31.2Vdc
Powerconsumption
(standby) —main
powersupply
300mA(12/24V)
Powerconsumption
(standby) —
SeaTalkng®power
supply
20mA(12V)
SeaTalkng ®LEN(Load
EquivalencyNumber)
1
SeaTalkng ®Powerout
3Aat12V(fuseprotectedat3A).
Dataconnections
SeaTalkng ®
EnvironmentalInstallationenvironment
•Operatingtemperature:-20ºCto+55ºC(-4ºFto+131ºF).
•Storagetemperature: -30ºCto+70ºC(-22°Fto+158°F).
•Relativehumidity:max93%.
•Waterproofrating:Dripresistant.
Dimensions
•Width:285mm(11.2in).
•Height:211.5mm(8.3in).
•Depth:64.5mm(2.5in).
130