EasyManuals Logo

Samsung AM160FNBFGB/EU User Manual

Samsung AM160FNBFGB/EU
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #245 background imageLoading...
Page #245 background image
Troubleshooting
4-100 Samsung Electronics
1. Inspection Method
4-4-56 Sump Sensor Error Due to Protection Control
No
Is the sensor connector
properly connected to PCB?
Is the sensor displaying
the temperature normally?
Is the sensor properly attached to
the sensor holder below the compressor?
Refer to the solution method
for the
liquid-compression prevention error (E477).
Re-connect and check the connector.
Yes
Yes
Yes
No
No
Re-attach and check sensor.
Check by referring to the other temperature
sensor problem check
-up methods.
Outdoor Unit Display
Indoor Unit Display
×(Operation)
(Reservation) (Blast) (Filter) ×(Defr ost)
Judgment Method t.BJOUBJOTVNQUFNQFSBUVSFPG¡$PSNPSFGPSGJWFNJOVUFT
Special Cause t$PNQSFTTPSMPBEJOHGBVMUZTVNQUFNQFSBUVSFTFOTPSGBVMUZ

Table of Contents