EasyManuals Logo
Home>Siemens>Industrial PC>SIMATIC IPC427D

Siemens SIMATIC IPC427D User Manual

Siemens SIMATIC IPC427D
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
Technical specifications
8.6 Hardware descriptions
SIMATIC IPC427D
Operating Instructions, 05/2017, A5E31347215-AB
133
8.6.4
I/O Address Areas
8.6.4.1
Overview of the internal module registers
The following addresses are used for the internal registers:
Addresses
Input/output unit
I/O 062h
Watchdog enable register / 066h select register (Page 133)
I/O 066h Watchdog
trigger register (watchdog enable register bit 2=0), watchdog trigger
register (watchdog enable register bit 2=1) (Page 134)
I/O 404Eh - 404Fh
Output register LED 1/2/3 and SF LED / RUN/STOP LED (Page 135)
I/O 50Ch
Battery status register (read-only) (Page 135)
See also
CAN base address register (Page 134)
8.6.4.2
Watchdog enable register / 066h select register (read/write, address 062h)
Meaning of the bits
Watchdog enable register / 066h select register (r/w address 062h)
Bit
Meaning of the bits
7
6
5
4
3
2
1
0
Watchdog enable bit (WDE)
0
Watchdog circuit disabled
1
Watchdog circuit enabled
Watchdog Mode
0
Standard
1
Macro
066h select register selection
0
Reserved
1
Scaler watchdog time (Normal/Macro)
0
0
0
94 ms / 2 s (default)
0
0
1
210 ms / 4 s
0
1
0
340 ms / 6 s
0
1
1
460 ms / 8 s
1
0
0
590 ms / 16 s
1
0
1
710 ms / 32 s
1 1 0 840 ms / 48 s
1
1
1
960 ms / 64 s

Table of Contents

Other manuals for Siemens SIMATIC IPC427D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC427D and is the answer not in the manual?

Siemens SIMATIC IPC427D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC427D
CategoryIndustrial PC
LanguageEnglish

Related product manuals