Technical specifications
9.7 Active Management Technology (AMT)
SIMATIC IPC477E PRO
148 Operating Instructions, 08/2017, A5E39912462-AA
9.7.4
Resetting the Intel® AMT to the default settings and disabling AMT
If Intel® AMT has already been configured, it is advisable to reset Inte AMT to the default
settings. One effect of resetting to the default settings is that Intel® AMT is disabled.
You can skip this point if you have a new IPC in the factory state.
Procedure
Proceed as follows to reset the Intel® AMT to the default values:
1. To open the BIOS selection menu, press the <ESC> key while the device is booting.
2. Open the BIOS Setup using "Setup Configuration Utility (SCU)".
3. Select the "Active Management Technology Support" command in the Advanced menu.
4. Activate the options "Intel AMT Configuration Screens" and "Un-Configure ME".
5. Exit BIOS with "F10" (Save and Exit)
6. The following prompt will appear after an automatic restart:
7. Confirm this prompt with "Y" to discard all settings in the Management Engine (ME).
The following message appears: "Unconfiguration in process...". The device is
automatically restarted.
9.7.5
Determining the network address
To connect the AMT PC with the AMT server, the network address that uniquely localizes
the AMT server on the AMT PC must be entered.
If DHCP is set for the automatic assignment of the network address in "Network Setup" in
the MEBx of the AMT PC, the network address is not fixed.
Procedure
If the AMT server uses the same network address as the operating system of the AMT PC
(most common situation):
1. You can obtain the address of the AMT server in the command line in Windows using
"ipconfig" and in UNIX using "ifconfig".
If the AMT server and operating system do not use the same network address, ask your
network administrator for the address you have been assigned.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC477E PRO and is the answer not in the manual?

Siemens SIMATIC IPC477E PRO Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC477E PRO
CategoryIndustrial PC
LanguageEnglish

Related product manuals