Further technical data
For further technical data such as the max. number of online connections, HMI devices that
can be used as well as a list of tasks available in the execution system, see the function
overview in the
PM 21 Catalog
,
Motion Control SIMOTION
,
SINAMICS S120
and
motors for
production machines
.
7.5 Digital inputs/outputs
Digital inputs
Table 7-11 Technical data for digital inputs
Number of inputs 4
Input voltage
Rated value
For signal "1"
For signal "0"
24 V DC
15 … 30 V
-3 … +5 V
Electrical isolation Yes, in groups of 4
Current consumption typical at 1 signal level 10 mA at 24 V
Input delay, typical (hardware) 0 → 1 signal: 50 µs
1 → 0 signal: 150 µs
Connection of a 2‑wire encoder
Permissible quiescent current
Possible
2 mA
Digital inputs/outputs
Table 7-12
Technical data regarding the digital I/Os with adjustable parameters
Quantity 4
(max.
3 as high-speed measuring input inputs,
max. 4 as high-speed cam outputs)
Table 7-13 Digital inputs/outputs when used as input
Input voltage
Rated value
For signal "1"
For signal "0"
24 V DC
15 … 30 V
-3 … +5 V
Electrical isolation no
Current consumption typical at 1 signal level 10 mA at 24 V
Technical data
7.5 Digital inputs/outputs
SIMOTION D410
90 Manual, 04/2014

Table of Contents

Other manuals for Siemens SIMOTION D410 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 DP and is the answer not in the manual?

Siemens SIMOTION D410 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410 DP
CategoryControl Unit
LanguageEnglish

Related product manuals