Further technical data
For further technical data such as the max. number of online connections, HMI devices that
can be used as well as a list of tasks available in the execution system, see the function
overview in the
PM 21 Catalog
,
Motion Control SIMOTION
,
SINAMICS S120
and
motors for
production machines
.
7.5 Digital inputs/outputs
Digital inputs
Table 7-11 Technical data for digital inputs
Number of inputs 4
Input voltage
● Rated value
● For signal "1"
● For signal "0"
● 24 V DC
● 15 … 30 V
● -3 … +5 V
Electrical isolation Yes, in groups of 4
Current consumption typical at 1 signal level 10 mA at 24 V
Input delay, typical (hardware) ● 0 → 1 signal: 50 µs
●
1 → 0 signal: 150 µs
● Connection of a 2‑wire encoder
●
Permissible quiescent current
● Possible
● 2 mA
Digital inputs/outputs
Table 7-12
Technical data regarding the digital I/Os with adjustable parameters
Quantity 4
(max.
3 as high-speed measuring input inputs,
max. 4 as high-speed cam outputs)
Table 7-13 Digital inputs/outputs when used as input
Input voltage
●
Rated value
● For signal "1"
● For signal "0"
● 24 V DC
● 15 … 30 V
● -3 … +5 V
Electrical isolation no
Current consumption typical at 1 signal level 10 mA at 24 V
Technical data
7.5 Digital inputs/outputs
SIMOTION D410