Manual Machine
7.7 Operation without machine control panel (MCP)
7-162
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Feedrate: 0 < Time feedrate < MD 32020 [1] $MA_JOG_VELO [1]
0 < Revolutional feedrate < MD 32050 [1] $MA_JOG_REV_VELO [1]
7.7 Operation without machine control panel (MCP)
If you wish to run the control system without machine control panel (MCP), then connect a
jumper between pin 24 and pin 5 to connector X1002 on the installed operator panel; other-
wise, the cotnrol system will not power up.
7.8 I/O assignment in the standard PLC program
The standard PLC program supplied with the Toolbox is designed for subsequent I/O assign-
ments where currently only modules of the DI/O16 type can be used.
7.8.1 Assignment of the digital inputs:
1st module:
I 0.0 * Reference switch X axis X2003 Pin 2 DI 0
I 0.1 * Reference switch Z axis X2003 Pin 3 DI 1
I 0.2 Limit position X axis X2003 Pin 4 DI 2
I 0.3 Limit position Z axis (tailstock collision switch) X2003 Pin 5 DI 3
I 0.4 X2003 Pin 6 DI 4
I 0.5 Chuck guard closed X2003 Pin 7 DI 5
I 0.6 Lubrication filling level X2003 Pin 8 DI 6
I 0.7 Lubrication pressure X2003 Pin 9 DI 7
I 1.0 X2004 Pin 2 DI 8
I 1.1 Protective door closed X2004 Pin 3 DI 9
I 1.2 Drive ready X2004 Pin 4 DI 10
I 1.3 * I2t monitoring of drive tripped X2004 Pin 5 DI 11
I 1.4 X2004 Pin 6 DI 12
I 1.5 X2004 Pin 7 DI 13
I 1.6 Spindle jogging key X2004 Pin 8 DI 14
I 1.7 X2004 Pin 9 DI 15