Installing the Control System
2.2 Interfaces and cables
2-19
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Interfaces
S X1 power supply terminals (DC24V)
4–pin screw–terminal block for connecting the 24 V load power supply
S X2 RS232 interface (AXIS)
25–pin sub–D plug connector for connecting ther power sections for max. 4 stepper motor
drives
S X3 spindle interface (SPINDLE)
9–pin D–Sub connector fr connecting a spindle drive with analog interface
S X4 measuring system interfaces (ENCD)
15–pin D–Sub female connector for connecting a position encoder (incremental, RS422)
S X8 RS232 drive interface (V24)
9–pin D–Sub connector
S X9 operator terminal interface (OPI)
25–pin D–Sub female connector for connecting the operator terminal
S X10 handwheel interface (MPG)
10–pin front connector for connecting the handwheels
S X20 BEROs (DI)
10–pin front connector for connecting fast inputs including BEROs and for wiring the NC
READY relay
DI/O
S X2003 and X2004
10–pin front connector for connecting digital inputs
S X2005 and X2006
10–pin front connector for connecting digital outputs
LEDs
3 LEDs for fault and status displays
Operating elements
Start–up switch S1