Protection level: 7
If you have deleted your password or do not set a password, you only have the access right
of viewing above-mentioned function areas.
Note
The system by default has no password.
Class
The "Class" field contains the data class to which the control-relevant data is assigned.
The data are divided into the following four data classes:
Data class Write rights Access right
S (System) System Access level 0
M (Manufacturer) Manufacturer Access levels 1 (password: SUNRISE)
I (Individual)
Note:
Individual machine data are grouped in this data class,
e.g. the leadscrew error compensation values.
Depending on the contents, these are accessible via dif‐
ferent access levels.
Manufacturer
or
Customer
Access levels 1 (password: SUNRISE)
or
Access level 3 (password: CUSTOMER)
U (User) Customer Access level 3 (password: CUSTOMER)
Access levels 4 to 6 (key-operated switch)
1)
1)
Access rights for
protection levels 4 to 6 are only suggestions and can be altered by the machine tool manufacturer or end
user.
2.2 Overview of the data
Machine and setting data (SINUMERIK)
The machine and setting data are divided into the following areas:
Range Designation
from 200 to 9999 Display machine data
from 10000 to 18999 General NC machine data
from 19000 to 19999 Reserved
from 20000 to 28999 Channel-specific machine data
from 29000 to 29999 Reserved
from 30000 to 38999 Axis-specific machine data
from 39000 to 39999 Reserved
from 41000 to 41999 General setting data
Explanation of machine data and setting data
2.2 Overview of the data
Parameter Manual