SINAMICS V70 parameters
7
7.1 Overview
The
chapter below
lists the parameters displayed on the BOP only. For more parameters about
the servo drive, refer to SINUMERIK 808D ADVANCED HMI through the following key
operations:
+ → → →
All parameters beginning with "p" are editable parameters, for example, p29000.
All parameters beginning with "r" are read-only parameters, for example, r0018.
Effective
Indicates the conditions for making parameterization effective. Two conditions are possible:
● IM (Immediately): Parameter value becomes effective immediately after changing.
● RE (Reset): Parameter value becomes effective after repower-on.
Can be changed
Indicates the state in which the parameter is changeable. Two states are possible:
● U (Run): Can be changed in the "Running" state. The "RDY" LED indicator lights up green.
● T (Ready to run): Can be changed in the "Ready" state. The "RDY" LED indicator lights up
red.
Data type
Type Description
I16 16-bit integer
I32 32-bit integer
U16 16 bits without sign
U32 32 bits without sign
Uint16 16-bit unsigned integer
Uint32 32-bit unsigned integer
Float 32-bit floating point number
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 487