7.2 V70 parameters on BOP
Par. No. Name Min Max Factory
setting
Unit Data type Effective Can be
changed
r0020 Speed setpoint smoothed - - - rpm Float - -
Description: Displays the currently smoothed speed setpoint at the input of the speed controller or U/f charac‐
teristic (after the interpolator).
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0021 Actual speed smoothed - - - rpm Float - -
Description: Displays the smoothed actual value of the motor speed.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0026 DC link voltage smoothed - - - V Float - -
Description: Displays the smoothed actual value of the DC link voltage.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0027 Absolute actual current smooth‐
ed
- - - Arms Float - -
Description: Displays the smoothed absolute actual current value.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
Dependency: r0068
r0029 Current actual value field-gen‐
erating smoothed
- - - Arms Float - -
Description: Displays the smoothed field-generating actual current.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0030 Current actual value torque-
generating smoothed
- - - Arms Float - -
Description: Displays the smoothed torque-generating actual current.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0031 Actual torque smoothed - - - Nm Float - -
Description: Displays the smoothed torque actual value.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
r0032 Active power actual value
smoothed
- - - kW Float - -
Description: Displays the smoothed actual value of the active power.
Significance for the drive: Power output at the motor shaft
r0033 Torque utilization smoothed - - - % Float - -
Description: Displays the smoothed torque utilization as a percentage.
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
SINAMICS V70 parameters
7.2 V70 parameters on BOP