NC setting data
4
41010 JOG_VAR_INCR_SIZE - H1
- Size of the variable increment for JOG DOUBLE Immediately
-
- - 0. - - 7/7 U
Description: This setting data defines the number of increments when variable increment (INCvar) is
selected. This increment size is traversed by the axis in JOG mode each time the
traverse key is pressed or the handwheel is turned one detent position and variable
increment is selected (PLC interface signal "Active machine function: INC variable"
for machine or
geometry axes is set to 1). The defined increment size also applies to
DRF.
Note:
Please note that the increment size is active for incremental jogging and handwheel
jogging. So, if a large increment value is entered and the handwheel is turned, the
axis
might cover
a large distance (depends on setting in MD31090 $MA_JOG_INCR_WEIGHT).
SD irrelevant to ......
JOG continuous
Related to ....
NC/PLC interface signal DB3300 DBX1001.5,1005.5,1009.5 (Geometry axis 1-3 active
machine function: INC variable) or NC/PLC interface signal DB390x DBX5.5 (Active
machine function: INC variable)
MD31090 $MA_JOG_INCR_WEIGHT (weighting of an increment for INC/handwheel)
41050 JOG_CONT_MODE_LEVELTRIGGRD - H1
- Jog mode / continuous operation with continuous JOG BOOLEAN Immediately
-
808d-me42 - TRUE 0 - 1/1 M
808d-me62 - TRUE 0 - 1/1 M
808d-te42 - TRUE 0 - 1/1 M
808d-te62 - TRUE 0 - 1/1 M
808d-mte40 - TRUE 0 - 7/7 U
808d-mte60 - TRUE 0 - 7/7 U
Description: 1: Jog mode for JOG continuous
In jog mode (default setting) the axis traverses as long as the traverse key is held
down
and an
axis limitation has not been reached. When the key is released the axis is
decelerated to zero speed and the movement is considered complete.
0: Continuous operation for JOG continuous
In continuous operation the traverse movement is started with the first rising edge of
the
traverse key
and continues to move even after the key is released. The axis can be
stopped again by pressing the traverse key again (second rising edge).
SD irrelevant for ......
Incremental jogging (JOG INC)
Reference point approach (JOG REF)
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 301