Signal state 0 The main run reads in preprocessed part program blocks.
corresponding to ... IS "Program status running"
Note for the reader
5.3 Signals from / to HMI
5.3.1 Program control signals from HMI
DB1700
DBX0.3
DRF selected
Signal(s) from HMI → PLC
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The operator has selected DRF on the operator panel front. The PLC pro‐
gram
(basic PLC
program or user program) transfers this HMI interface signal
to the interface signal corresponding to the logic operation:
Activate DRF.
As soon as DRF is active, the DRF offset can be changed in the AUTOMATIC
or MDI mode using the handwheel assigned to the axis.
Signal state 0 The operator has not selected DRF on the operator panel front.
corresponding to ... JOG mode
Note for the reader Activate DRF
DB1700
DBX0.5
M01 selected
Signal(s) from HMI → PLC
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 Activate program control M1 has been selected from the operator interface.
This does not activate the function.
Signal state 0 Activate program control M1 has not been selected from the operator inter‐
face.
corresponding to ... IS "Activate M01"
IS "M0/1 active"
Note for the reader Function Manual Basic Functions K1
DB1700
DBX0.6
Dry run feedrate selected
Signal(s) to channel (HMI → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 Dry run feedrate is selected.
Instead of the programmed feedrate, the dry run feedrate entered in SD
42100: DRY_RUN_FEED is active.
When activated from the operator panel, the dry run feedrate signal is auto‐
matically
entered in
the PLC interface and transferred by the PLC basic pro‐
gram to the PLC interface signal "Activate dry run feedrate".
Detailed descriptions of interface signals
5.3 Signals from / to HMI
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 357

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals