Signal state 0 Dry run feedrate is not selected.
The programmed feedrate is active.
corresponding to ... IS "Activate dry run feedrate" (DB3200 DBX0.6)
SD: DRY_RUN_FEED (dry run feedrate)
Note for the reader Function Manual Basic Functions V1, K1
DB1700
DBX1.3
Feedrate override selected for rapid traverse
Signal(s) to channel (HMI → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The feedrate override switch should also be active as rapid traverse override
switch.
Override values above 100% are limited to the maximum value for 100%
rapid traverse override.
The IS "Feedrate override for rapid traverse selected" is automatically en‐
tered
from the
operator panel into the PLC interface and is transferred from
the basic PLC program to the PLC interface signal "Rapid traverse override
active".
Further, the IS "Feedrate override" (DB3200 DBB4) is copied from the
basic PLC program into the IS "Rapid traverse override" (DB3200 DBB5).
Signal state 0 The feedrate override switch should not be activated as rapid traverse over‐
ride switch.
Application The signal is used when no separate rapid traverse override switch is avail‐
able.
Note for the reader Function Manual Basic Functions V1
DB1700
DBX1.7
Program test selected
Signal(s) from HMI → PLC
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 Program control program test has been selected from the operator interface.
This does not activate the function.
Signal state 0 Program control program test has not been selected from the operator inter‐
face.
corresponding to ... IS "Activate program test"
IS "Program test active"
Note for the reader Function Manual Basic Functions V1
DB1700
DBX2.0 to 3.1
Skip block selected
Signal(s) from HMI → PLC
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 Program control skip block has been selected from the operator interface.
This does not activate the function.
Signal state 0 Program control – skip block – has not been selected from the operator in‐
terface.
corresponding to ... IS "Activate skip block"
Note for the reader Function Manual Basic Functions K1
Detailed descriptions of interface signals
5.3 Signals from / to HMI
Parameter Manual
358 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals