corresponding to ... IS "Active machine function 1 INC, ..."
for axis 1 in the Work (DB3300 DBX1001.0 ... .6)
for axis 2 in the Work (DB3300 DBX1005.0 ... .6)
for axis 3 in the Work (DB3300 DBX1009.0 ... .6)
IS "INC inputs active in the mode group area" (DB2600 DBX1.0)
Note for the reader Function Manual Basic Functions H1
5.7.2 Signals from NC channel
DB3300
DBX0.3
Action block active
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 Block search: Output of the collective auxiliary functions running.
Note for the reader Function Manual Basic Functions K1
DB3300
DBX0.4
Approach block active
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 Block search with calculation / at contour: Approach block running
Note for the reader Function Manual Basic Functions K1
DB3300
DBX0.5
M0/M1 active
Signal(s) from channel (NCK → PLC)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The part program block is executed, the auxiliary functions are output, and
●
M0 is located in the work memory, or
● M1 is in the work memory and IS "Activate M01" is active
The program status changes to stopped.
Signal state 0
●
With IS "NC start"
● For a program abort as a result of a reset
Detailed descriptions of interface signals
5.7 Channel-specific signals
Parameter Manual
392 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1