Signal state 1 2nd software limit switch for the plus or minus direction is active.
1st software limit switch for the plus or minus direction is inactive.
In addition to the 1st software limit switches (plus or minus), 2nd software
limit switch (plus or minus) can be activated via these interface signals.
The position is defined using MD36130 POS_LIMIT_PLUS2,
MD36120 POS_LIMIT_MINUS2 (2nd
software limit switch plus, 2nd software
limit switch minus).
Signal state 0 1st software limit switch for the plus or minus direction is active
2nd software limit switch for the plus or minus direction is inactive
Note for the reader Function Manual Basic Functions A3
DB380x
DBX1000.7
Reference point approach deceleration
Signal(s) to axis / spindle (PLC → NCK)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 The machine axis is positioned at the reference cam.
Signal state 0 The machine axis is positioned in front of the reference cam. An appropriately
long reference cam (up to the end of the traversing range) should be used
to
prevent the machine axis from being located behind (after) the referencing
cam.
Note for the reader Function Manual Basic Functions R1
DB380x
DBX1002.1
Activate the program test
Signal(s) to axis / spindle (PLC → NCK)
Edge evaluation: No Signal(s) updated: Cyclic
Signal state 1 Activation of the program test is requested.
During the program test, all motion commands of axes (not spindles) take
place under "Axis disable."
Notice!
Because of the axis disable, the assignment of a tool magazine is not
changed during program testing. The user/machine manufacturer must uti‐
lize a suitable PLC user program to ensure that the NCK-internal tool man‐
agement and the
actual assignment of the tool magazine remain consistent.
Refer to the program example included in the PLC Toolbox.
Signal state 0 Activation of the program test is not requested.
corresponding to ... DB1700 DBX1.7 (program test selected)
DB3300 DBX1.7 (program test active)
Note for the reader Function Manual Basic Functions K1
DB380x
DBX2000.0 to .2
Actual gear stage A to C
Signal(s) to axis / spindle (PLC → NCK)
Edge evaluation: Yes Signal(s) updated: Cyclic
Detailed descriptions of interface signals
5.8 Axis / spindle-specific signals
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 419