13 Machine-related protection zone violated
Area 10 Area 9
14 Channel-specific protection zone violated
Area 8 Area 7 Area 6 Area 5 Area 4 Area 3 Area 2 Area 1
15 Channel-specific protection zone violated
Area 10 Area 9
Status signals, axes in Work
DB3300 Signals from NCK channel [r]
NCK -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
1000 Axis 1 in Work
Travel command Travel request Handwheel active (bit/binary coded)
1)
Plus Minus Plus Minus 2 1
1001 Axis 1 in Work
Machine function
2)
Continuous
traversing
Var. INC 10000 INC 1000 INC 100 INC 10 INC 1 INC
1002
1003
Contour
handwheel
direction of
rotation in‐
verted
1004 Axis 2 in Work
Traversing command Travel request Handwheel active (bit/binary coded)
Plus Minus Plus Minus 2 1
1005 Axis 2 in Work
Machine function
Continuous
traversing
Var. INC 10000 INC 1000 INC 100 INC 10 INC 1 INC
1006
1007
Contour
handwheel
direction of
rotation in‐
verted
1008 Axis 3 in Work
Traversing command Travel request Handwheel active (bit/binary coded)
Plus Minus Plus Minus 2 1
PLC user interface
6.8 Channel signals
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 473