11110 AUXFU_GROUP_SPEC N07 H2
- Auxiliary function group specification DWORD PowerOn
-
808d-me42 168 0x8081, 0x8021,
0x8041, 0x8041,
0x8041, 0x8041,
0x8041, 0x8041...
0 0x7FFFFFFF 1/1
808d-me62 168 0x8081, 0x8021,
0x8041, 0x8041,
0x8041, 0x8041,
0x8041, 0x8041...
0 0x7FFFFFFF 1/1
808d-te42 168 0x8081, 0x8021,
0x8041, 0x8041,
0x8041, 0x8041,
0x8041, 0x8041...
0 0x7FFFFFFF 1/1
808d-te62 168 0x8081, 0x8021,
0x8041, 0x8041,
0x8041, 0x8041,
0x8041, 0x8041...
0 0x7FFFFFFF 1/1
808d-mte40 168 0x81, 0x21, 0x41,
0x41, 0x41, 0x41,
0x41, 0x41...
0 0x7FFFFFFF 1/1
808d-mte60 168 0x81, 0x21, 0x41,
0x41, 0x41, 0x41,
0x41, 0x41...
0 0x7FFFFFFF 1/1
Description: Defines the output options for the auxiliary functions belonging to a group.
However, the output option of an auxiliary function configured by MD22080
$MC_AUXFU_PREDEF_SPEC[ preIndex ] or MD22035 $MC_AUXFU_ASSIGN_SPEC[ auxIndex ] has a
higher priority.
Bit 0=1 "Normal" acknowledgement after an OB1 cycle
Bit 1=1 "Quick" acknowledgement with OB40
Bit 2=1 No predefined auxiliary function
Bit 3=1 No output to PLC
Bit 4=1 Spindle response after acknowledgement by the PLC
Bit 5=1 Output prior to motion
Bit 6=1 Output during motion
Bit 7=1 Output at end of block
Bit 8=1 No output after block search types 1, 2, 4
Bit 9=1 Collection during block search type 5 (SERUPRO)
Bit 10 = 1 No output during block search type 5 (SERUPRO)
Bit 11 = 1 Cross-channel auxiliary function (SERUPRO)
Bit 12 = 1 Output via synchronized action
Bit 13 = 1 Implicit auxiliary function
Bit 14 = 1 Active M01
Bit 15 = 1 No output during running-in test
Bit 16 = 1 Nibbling off
Bit 17 = 1 Nibbling on
Bit 18 = 1 Nibbling
The MD must be defined for each existing auxiliary function group.
The index [n] corresponds to the auxiliary function group: 0...63
Machine data
3.2 General machine data
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 59