EasyManuals Logo
Home>Siemens>Control Unit>SINUMERIK 808D ADVANCED

Siemens SINUMERIK 808D ADVANCED Parameter Manual

Siemens SINUMERIK 808D ADVANCED
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
11470 REPOS_MODE_MASK EXP, N01 K1
- Repositioning properties DWORD PowerOn
-
- - 0x8 0 0xFFFF 1/1
Description: This bit mask can be used to set the behavior of the control during repositioning.
Bit no. Meaning when bit set
-----------------------------------------------------------------------------
0 (LSB)
The dwell time is continued in the residual block from where it was interrupted. (If
the bit is not set, the dwell time is repeated completely).
1 Reserved
2 When the bit is set, the repositioning of individual axes can be prevented or
delayed via the VDI interface.
3 When the bit is set, positioning axes are repositioned in the approach block
during search run via program test.
4 As 3, but after every Repos, not only during search run.
5 When the bit is set, changed feeds and spindle speeds already become valid in the
residual block, otherwise not until the following block.
6 When the bit is set, neutral axes and positioning spindles are repositioned after
SERUPRO as command axes in the approach block.
7 The bit changes the behavior of the VDI-AXIN interface signal "Repos Delay". The
level
of "Repos
Delay" is read if REPOSA is interpreted. Axes that are neither geo nor
orientation axes are then excluded from the REPOS, that is REPOS does NOT move these
axes.
11510 IPO_MAX_LOAD N01, N05 -
% Max. permitted IPO load DOUBLE PowerOn
-
- - 0.00 0.0 100.0 1/1
Description: Enable utilization analysis via synchronized actions.
This MD11510 $MN_IPO_MAX_LOAD sets the IPO computing time (in % of the IPO cycle) after
which the variable $AN_IPO_LOAD_LIMIT is to be set to TRUE. The variable is reset to
FALSE if the value falls below this after having once exceeded it.
This diagnostics function is disabled if the machine data is 0.
11550 STOP_MODE_MASK N01 V1
- Defines the stop behavior. DWORD PowerOn
-
- - 0 0 0x1 2/2
Description: This MD describes the stop behavior of the NCK under certain conditions:
Bit no. Meaning
Bit 0 == 0 :=
No stop if G codes G331/G332 are active and a path motion or G4 has also been
programmed.
Bit 0 == 1 :=
Same behavior as until SW version 6.4, i.e. a stop is possible during G331/G332.
Bits 1.....15
Not assigned
Machine data
3.2 General machine data
Parameter Manual
72 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals