4 Mechanical Mounting User Manual
NOTICE
When installing devices, ensure that no device in the system causes it hard for the
DC switch and the AC circuit breaker to act or hinders maintenance personnel from
operating.
If drilling is required during installation:
Wear goggles and protective gloves when drilling holes.
Make sure to avoid the water and electricity wiring in the wall before drilling.
Protect the product from shavings and dust.
4.2   Location Requirements
To a large extent, a proper installation location ensures safe operation, service life, and per
formance of the inverter.
The inverter with protection rating IP66 can be installed both indoors and outdoors.
The inverter should be installed at a height that allows easy viewing of the LED indicator
panel, as well as easy electrical connection, operation and maintenance.
4.2.1 Environment Requirements
The installation environment must be free of inflammable or explosive materials.
The location should not be accessible to children.
The ambient temperature and relative humidity must meet the following requirements.
20

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG125CX-P2 and is the answer not in the manual?

Sungrow SG125CX-P2 Specifications

General IconGeneral
Max. DC Voltage1100 V
Rated AC Power125 kW
Max. DC Power150 kW
Start-up Voltage200 V
MPPT Voltage Range200 V - 1000 V
Max. Short-circuit Current per MPPT40 A
Max. AC Power137.5 kW
Max. AC Current198 A
Rated AC Voltage400 V
Rated Grid Frequency50/60 Hz
Total Harmonic Distortion<3%
Power Factor Adjustment Range0.8 leading to 0.8 lagging
DC Connection TypeMC4
Protection ClassIP66
Maximum DC Input Power150 kW
DC Inputs per MPPT2
Cooling MethodSmart forced air cooling
Operating Temperature Range-25°C to +60°C
Humidity Range0 - 100%
CommunicationRS485, Ethernet