6-26 ELECTRICAL SYSTEM
STARTER RELAY INSPECTION
• Remove the seat. (!5-4)
• Pull out the starter relay and remove the luggage box.
(!5-4)
• Disconnect the battery
î›§
- lead wire from the battery.
(!6-11)
• Remove the starter relay cover
î›§
1.
• Disconnect the starter motor lead wire
î›§
2, battery
î›§
+ lead wire
î›§
3 and starter relay coupler
î›§
4.
• Remove the starter relay.
• Apply 12 V to
î›§
A and
î›§
B terminals and check for continuity
between the positive and negative terminals using the multi-
circuit tester. If the starter relay clicks and continuity is found,
the relay is ok.
" 09900-25008: Multi-circuit tester set
* Tester knob indication: Continuity test (+)
#
Check the relay coil for opens, grounds and the specified resis-
tance.
$ Starter relay resistance
Standard: 3 – 6 Ω
0 Tester knob indication: Resistance (Ω)
Do not apply battery voltage to the starter relay for five
seconds and more, since the relay coil may overheat
and get damaged.
To starter motor -+ To battery