| The specifications of the spare parts to be used, when these affect the health and safety of operators
S.1.1.2 Configuration of frequency converters with installed guard
A frequency converter is mounted beside the fan in some units. If the configuration of frequency is carried out with the
fan in operation, the guard must be installed for safety reasons and a long cable must be installed between the fre-
quency converter inside the unit and the control panel outside the unit.
S.1.2 Safe adjustment and maintenance
Before maintenance and repair, the unit must be switched off by switching off the automatic circuit breakers and block
them by padlocks. Note that lamps must be switched on during maintenance (lamps are an accessory only installed,
if ordered).
Use cut-resistant gloves for protection against injury from sharp metal plate edges. Use CE-marked gloves for this pur-
pose. Use helmet during maintenance work in the unit.
S.1.3 Personal protective equipment for maintenance staff health and safety
Use the below-mentioned personal protective equipment for maintenance:
Cut-resistant gloves for protection against injury from sharp metal plate edges. Use CE-marked gloves for this
purpose.
Helmet
Particulate respirator maintenance free including foam face-seal and adjustable pre-threaded headbands for re-
placing filters.
Padlock for locking the above mentioned automatic circuit breakers.
Permanent magnet motor. The shaft must be blocked during repairs and maintenance of the electric system (the
motor generates electricity by rotation for example that the wind and thermic drives the fan/motor).
T The specifications of the spare parts to be used, when these affect the health
and safety of operators
Geniox air handling units are operating automatically. Operators can control the unit by the Systemair control panel
T.1 Spare parts - Mechanical
Annex 3 - available on demand
T.2 Spare parts - Electrical
Annex 3 - available on demand
U Information on airborne noise emissions exceeding 70 dB(A)
Due to the design and construction of the units the (A) weighed sound pressure level from fans and other components
do not exceed 70 dB (A) outside the units.
output |

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SystemAir Geniox 12 and is the answer not in the manual?

SystemAir Geniox 12 Specifications

General IconGeneral
BrandSystemAir
ModelGeniox 12
CategoryAir Handlers
LanguageEnglish

Related product manuals