11
Total Control Systems www.tcsmeters.com
TYPE 1 TYPE 2
TYPE 3
CALIBRATION SCREEN
Temperature Calibration screen will show volume/mass and Temperature
Flowrate Calibration screen will show volume/mass and Flowrate
Empty Calibration screen will show volume/mass and nothing else
BRIGHTNESS
Brightness allows you to set the brightness of the display screen from 100 to 30 percent (brightest to dimmest)
settings.
NET TOTALIZER Net Totalizer allows you to set whether the Net Totalizer is visible on the display screen.
Always Net Totalizer is always visible
Auto Net Totalizer is visible only when a product has Automatic Temperature Correction
(ATC) enabled on a Product
Never Net Totalizer is never visible
GROSS TOTALIZER
Gross Totalizer allows you to set whether the Gross or Volume Totalizer is visible on the display screen.
Volume Totalizer Volume Totalizer is always visible
Mass Totalizer Mass Totalizer is always visible
3) PRINTER SETTINGS
ENABLE/DISABLE PRINTER
Enable Allows the printer to operate. Highlight Enable and select ENTER. When
the printer is Enabled, a printer icon will appear in the top left portion of the screen.
Disable Will not allow the printer to operate. Highlight Disable and select ENTER. When
the printer is Disabled, the little printer will disappear in the top left portion of the
screen.
TYPE 4
* TYPE 4 Only displays delivered volume.
System Settings
2) DISPLAY SETTINGS
DEFAULT SCREEN Select the Type of Screen you would like the TCS 3000 to default to.
TYPE 5