WEIGHTS & MEASURES SETTINGS TROUBLESHOOTING (CONTINUED)
PROBLEM PROBABLE CAUSE SOLUTION
Preset Valve will not open. Solenoids are inacve or
inoperave. Foreign de-
bris in system.
1. Start a delivery and listen for the audible clicking sound from
the solenoids.
2. If there is an audible click from the solenoid (but sll no ow),
this may be an indicaon of a mechanical problem with the
main valve or its associate components.
3. If there is NO audible click form the solenoid, check the voltage
to Pin + and 0V of terminal block Solenoid 1. While the
TCS3000 is sll in delivery, use a reliable mulmeter to meas-
ure the following DC voltages on the circuit board. Use 0 pin as
a ground or frame ground.
TERMINAL SOLENOID 1 for 2 VOLTAGE
9.0 VDC with plug remove VDC (NO LOAD)
2.0 VDC with solenoid connected
12.0 VDC with the solenoid energized
4. If the above voltages are correct, this may be an indicaon of a
problem with the valve or its associated components.
5. Check for pinched 50 pin communicaon cable in register.
6. If the above voltage are NOT correct, replace the Solenoids
and/or TCS3000 terminal board.
Preset Valve doesn’t shut
o or pulsates
Valve was never set-up
and calibrated.
1. Valve sengs by product are not correctly setup. Check the
following W&M -> Product Sengs for minimum values:
- S1-S2 Delay should be 2 seconds or more.
- S2 Delay should be 0.2 seconds or more.
- Maximum Flow Rate should be at least the maximum ow
rate of ow meter.
2. Run full calibraon, followed by Full Auto preset seng. Allow
preset to run in its enrety. NOTE: S2 is set for 20% of preset
value.
3. If preset solenoids connue to click, double the Maximum Flow
Rate within Product Parameters.
Delivery does not begin at
Zero
Hose Charge is set too high Hose Charge under Product Parameters is set too high. Change
accordingly. NOTE: Hose Charge can be disabled.
Maximum Pulser Error Noise from truck is cre-
ang false pulse transmis-
sions
1. Make sure that pulser cable leads are foil wrapped with a shield
drain
2. Only terminate the shield drain to the TCS 3000 register, and
not the Direct Mount Pulser.
3. Change Maximum Pulser Error to maximum allowable error of
255.
4. Direct Mount Pulser has a shunt for 5V and 9-30V, check that
the shunt is on 5V
5. Ferrite Coupling over pulse encoder cable.
6. Insulate the TCS 3000 register from chassis and place ground to
baery.
Missing Pulse Channel Error One pulse channel is miss-
ing from the Dual or Quad-
rature pulser seng or
pulse encoder has failed.
1. Check wiring of the A and B channel wiring on the TCS 3000
register for good terminaon.
2. Direct Mount Pulser has two LED indicaons for each channel.
If product is owing and one of these is not lit, then we have a
bad encoder and it needs changed.
3. Direct Mount Pulser has a shunt for 5V and 9-30V, check that
the shunt is on 5V

Table of Contents

Other manuals for TCS 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TCS 3000 and is the answer not in the manual?

TCS 3000 Specifications

General IconGeneral
BrandTCS
Model3000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals