PERFORMANCE
CHECK
PROCEDURE
Introduction
This
procedure
checks
the
electrical
performance
re
quirements
as
listed
in
the
Specification
section
in
this
man
ual
.
Perform
the
adjustment
procedure
if
the
instrument
fails
to
meet
these
checks
.
If
readjustment
does
not
correct
the
discrepancy
,
circuit
troubleshooting
is
indicated
.
Also
,
use
this
procedure
to
determine
acceptability
of
performance
in
an
incoming
inspection
facility
.
For
convenience
,
some
steps
in
this
procedure
check
the
performance
of
these
in
struments
at
only
one
value
in
the
specified
range
.
Any
val
ue
within
appropriate
limits
,
may
be
substituted
.
The
performance
check
may
be
done
at
any
ambient
tempera
ture
between
°
C
and
+
50
°
C
.
Description
Power
Module
Oscilloscope
System
Differential
Comparator
Amplifier
Sampling
System
Spectrum
Analyzer
Distortion
Analyzer
Precision
Digital
Voltmeter
Precision
μA
Meter
Square
Wave
Generator
Universal
Counter
/
Timer
Digital
Multimeter
REV
JUL
1982
Minimum
Requirement
Table
5-1
TEST
EQUIPMENT
REQUIRED
Two
Compartments
GPIB
Compatible
Minimum
Vertical
Deflection
Factor
,
.5
V
/
div
.
Fastest
calibrated
Sweep
Rate
,
.05
μs
.
0.1
%
of
Setting
+3
mV
1
GHz
Bandwidth
10
ns
Risetime
Frequency
range
,
100
kHz
to
20
MHz
30
dB
resolution
Frequency
Range
,
20
Hz
to
100
kHz
5
1/2
digits
to
10
μV
5
1/2
digits
to
10
μA
+1
V
to
1
V
1
kHz
Square
Wave
Range
- To
20
MHz
freq
,
Function
-
Time
A
B
period
4
1/2
digits
to
±
35
Volts
Test
Equipment
Required
The
test
equipment
listed
in
Table
5-1
,
or
equivalent
,
is
suggested
to
do
the
performance
check
or
adjustment
procedure
.
In
the
following
procedures
,
all
test
conditions
for
the
FG
5010
are
power
up
conditions
unless
otherwise
specified
.
Perf
.
Check
Step
All
Steps
2,7,8,9,10,13
2
LO
5
4
4
1,6,8,11,12
3
ΝΟΤΕ
Adj
.
Proc
.
Step
All
Steps
7,8,10,13,14
,
15,16,18,19
,
20,21,22,24
7,8,10,13,14
,
15,16,18,19
20,22,24
21
23
Section
5
-
FG
5010
4,5
6
8,25
11,12,25
1,2,3,9,17,19
Recommended
Equipment
TEKTRONIX
TM
5003
TEKTRONIX
7704A
/
7A16A
/
7B50A
TEKTRONIX
7A13
TEKTRONIX
7704A
/
7S11
/
S
-
1
/
7T11
TEKTRONIX
7704A
/
7L12
TEKTRONIX
AA501
Fluke
8502A
Fluke
8502A
Opt
3
TEKTRONIX
FG
503
TEKTRONIX
DC503A
Prec
DVM
5-1