Command Groups
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2-17
Ethernet Commands
Ethernet commands let you remotely set oscilloscope ethernet settings. Table 2--9
lists these commands. Ethernet commands are available only in the
TDS3000B
and TDS3000C Series
oscilloscopes, or in TDS3000 S eries oscilloscopes equipped
with an optional TDS3EM Ethernet communications module.
Table 2- 9: Ethernet comm ands
Header Description
ETHERnet:DCHPBOOTP Sets or returns DCHP/BOOTP function status
ETHERnet:DNS:IPADDress Sets or returns the Domain Name Server
(DNS) address stored in the oscilloscope
ETHERnet:DOMainname Sets or returns the Domain Name Server
(DNS) name stored in the oscilloscope
ETHERnet:ENETADDress? Returns the factory-set ethernet address of the
TDS3EM module or oscilloscope
ETHERnet:GATEWay Sets or returns the Gateway IP address value
ETHERnet:HTTPPORT Sets or returns the HTTP port value stored in
the oscilloscope
ETHERnet:IPADDress Sets or returns the IP address of the oscillo-
scope
ETHERnet:NAME Sets or returns the oscilloscope instrument
name
ETHERnet:NETPRInter:ADD Adds the specified printer to the oscilloscope
ethernet printer list
ETHERnet:NETPRInter:DELEte Deletes the specified printer from the
oscilloscope ethernet printer list
ETHERnet:NETPRInter:DELWarn Enables or disables displaying a warning
message when deleting a printer
ETHERnet:NETPRInter:REName Renames the specified ethernet printer
ETHERnet:NETPRInter:SELect:
ALLInfo?
Returns the selected (active) printer configura-
tion information
ETHERnet:NETPRInter:SELect:NAME Sets or returns the identity of the selected
(active) ethernet printer
ETHERnet:PASSword Sets the ethernet password
ETHERnet:PING:EXECUTE Test s the Ethernet connection
ETHERnet:PING:STATUS? Returns results of Ethernet connection testing
ETHERnet:SUBNETMASK Sets or returns the Ethernet subnet mask
value