ElectricalSystem
Maintenance
ElectricalSystemSafety
•Disconnectthebatterybeforerepairingthe
machine.Disconnectthenegativeterminalrst
andthepositivelast.Connectthepositiveterminal
rstandthenegativelast.
•Chargethebatteryinanopen,well-ventilated
area,awayfromsparksandames.Unplugthe
chargerbeforeconnectingordisconnectingthe
battery.
•Wearprotectiveclothinganduseinsulatedtools.
ReplacingtheFuses
Thefuseblockfortheelectricalsystemislocated
beneaththeoperator'sseat(Figure82).
g034159
Figure82
1.Openslot9.Openslot
2.Worklight
10.Openslot
3.Ignition
11.InfoCenter
4.TEClogic
12.Tankspray
5.TECpower13.Cruisecontrol
6.TECpower14.USBpower
7.Extrafuseslot
15.Boomandheadlight
8.Boomcontrol
16.TECpower
ServicingtheBattery
Alwayskeepthebatterycleanandfullycharged.Use
apapertoweltocleanthebatteryandbatterybox.If
thebatteryterminalsarecorroded,cleanthemwith
asolutionof4partswaterand1partbakingsoda.
Applyalightcoatingofgreasetothebatteryterminals
topreventcorrosion.
Voltage:12Vwith690coldcrankingampsat0°F
(-18°C)
RemovingtheBattery
1.Positionthesprayeronalevelsurface,engage
theparkingbrake,shutoffthespraypump,shut
offtheengine,andremovethekey.
2.Removethebatterycoveranddisconnectthe
negative(black)groundcablefromthebattery
post(Figure83).
g014029
Figure83
1.Batterycover3.Buckle
2.Strap
WARNING
Incorrectbatterycableroutingcould
damagethesprayerandcables,causing
sparks.Sparkscancausethebattery
gassestoexplode,resultinginpersonal
injury.
•Alwaysdisconnectthenegative
(black)batterycablebefore
disconnectingthepositive(red)
cable.
•Alwaysconnectthepositive(red)
batterycablebeforeconnectingthe
negative(black)cable.
63