BA ET16 de* 1.0 * et16w700.fm 7-7
Maintenance 7
Maintenance schedule of Lehnhoff mechanical quickhitch system
Other maintenance intervals (Wacker Neuson service center):
• Every 250 hours of operation or semi-annually
• Every 500 operating hours or annually
For additional details contact a Wacker Neuson service center.
L
L
L
M
M
G
H H
J
L
L
K
K
Symbolic representa-
tions
Quick coupler system MS01 maintenance (operator) Interval
1
Perform visual inspection of the quickhitch system --
10 hours of operation/
daily
Clean bolt guide G
50 hours of operation/
weekly
Clean the bolt contact surface H
50 hours of operation/
weekly
Clean bottom side of the quick coupler system J
50 hours of operation/
weekly
Clean contact surfaces of the attachment K
50 hours of operation/
weekly
Clean the opening for the socket wrench and bores of the attachment support L
50 hours of operation/
weekly
Clean bolt attachment support M
50 hours of operation/
weekly
1. For time specifications: the first achieved time specification is decisive. If the situation requires it, perform maintenance if necessary, even if the maintenance
interval has not yet been reached.