EasyManuals Logo
Home>Wacker Neuson>Excavators>ET16

Wacker Neuson ET16 User Manual

Wacker Neuson ET16
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
BA ET16 de* 1.0 * et16w700.fm 7-7
Maintenance 7
Maintenance schedule of Lehnhoff mechanical quickhitch system
Other maintenance intervals (Wacker Neuson service center):
Every 250 hours of operation or semi-annually
Every 500 operating hours or annually
For additional details contact a Wacker Neuson service center.
L
L
L
M
M
G
H H
J
L
L
K
K
Symbolic representa-
tions
Quick coupler system MS01 maintenance (operator) Interval
1
Perform visual inspection of the quickhitch system --
10 hours of operation/
daily
Clean bolt guide G
50 hours of operation/
weekly
Clean the bolt contact surface H
50 hours of operation/
weekly
Clean bottom side of the quick coupler system J
50 hours of operation/
weekly
Clean contact surfaces of the attachment K
50 hours of operation/
weekly
Clean the opening for the socket wrench and bores of the attachment support L
50 hours of operation/
weekly
Clean bolt attachment support M
50 hours of operation/
weekly
1. For time specifications: the first achieved time specification is decisive. If the situation requires it, perform maintenance if necessary, even if the maintenance
interval has not yet been reached.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson ET16 and is the answer not in the manual?

Wacker Neuson ET16 Specifications

General IconGeneral
BrandWacker Neuson
ModelET16
CategoryExcavators
LanguageEnglish

Related product manuals