7-32 BA ET16 de* 1.0 * et16w700.fm
7 Maintenance
Checking the coolant level
1. Stop and park the machine. Stop the engine. See “Preparing
lubrication”.
2. Carefully unscrew filler cap C and release the pressure.
3. Perform a visual inspection of the water cooler B.
4. If the coolant level is below the marking LOW of the compensation
container A or the coolant does not reach to the filler neck of the water
cooler B:
Add coolant.
Information
Check the coolant level once a day before starting the engine.
Observe the coolant compound table
Adding coolant
1. Stop and park the machine. Stop the engine. See “Preparing
lubrication”.
2. Carefully unscrew filler cap C and release the pressure.
3. Open filler cap C.
4. Top off coolant up to the lower edge of the filler neck.
5. Close filler cap C.
6. Start the engine and let it warm up for about 5 – 10 minutes.
7. Stop the engine.
8. Remove the starting key and carry it with you.
9. Let the engine cool down.
10.Check the coolant level again.
The coolant level must be between the LOW and FULL marks.
11.If necessary, add coolant and repeat the procedure until the coolant
level remains constant.
12.Close and lock the engine cover.
Fig. 233
B
A
C
LOW
FULL