Maintenance
Drive unit/diesel engine
BA RD24_RD27 en 04
141
4
312
Changing safety cartridge
Switch off diesel engine and remove ignition key.
Allow machine to cool down less than 30 °C (86 °F).
Fold up the clips [1].
Remove dust container [2].
Clean the inside of the dust container.
Pull the air filter cartridge [3] out of the air filter.
Pull out safety filter cartridge [4].
Slide in a new safety cartridge.
Slide a new air filter cartridge [3] into the air filter.
Put on the dust receiver bin [2].
Snap shut the clips [1].
Check the operating readiness of the air filter.
4.03.08 Checking/cleaning the radiator
NOTICE
High water pressure by high-pressure cleaner!
Damage of radiator when cleaning with high-pressure cleaner.
Maintain a safe distance between the lance of the high-pressure
cleaner and the radiator.
Use a directed spray.
Guide the directed spray parallel (not at an angle) to the cooling
fins of the radiator.