Maintenance
Water sprinkling
BA RD24_RD27 en 04
159
4.08 Water sprinkling
NOTICE
Corrosion and frost!
Material damage to sprinkler installations due to corrosion and frost.
While the machine is going to be parked for an extended period of time
and/or in case of danger of freezing:
Empty and clean the water sprinkling unit/additive sprinkling
system.
Remove and clean the sprinkler nozzles.
Carry out antifreeze work, if available.
4.08.01 Sprinkler nozzle inspection
NOTE
Check that an even sprinkling pattern is obtained on the roller
drums/tyres.
31 4 2
Prerequisites
Diesel engine off
Electrical system on
Parking brake activated
For water sprinkling: Drive lever in F position (forward)
Sprinkler nozzle check for water sprinkling
Press switch [1].
a
Water sprinkling is done by intermittent operation at the preset
interval level.
Press and hold the foot switch [2].
a
The water sprinkler will be active as long as the foot switch is being
pressed.
Press the switch [1] once again or release the foot switch [2].
a
Water sprinkling off.
Latch driving lever in position 0.
Switch off the electrical system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RD24 and is the answer not in the manual?

Wacker Neuson RD24 Specifications

General IconGeneral
BrandWacker Neuson
ModelRD24
CategoryConstruction Equipment
LanguageEnglish

Related product manuals