Operation
Starting the machine
82
BA RD24_RD27 en 04
3.14 Starting the machine
Requirement: Fill levels for the operating materials, for example fuel,
water etc., are adequate.
Before starting the machine, check all functions and settings (see
"Function tests before starting work").
NOTE
The electrical system is switched on and off and the diesel
engine started and stopped with the ignition key.
2
1
0
I
II
III
[1] Ignition key [2] Cold start assistance pilot lamp
NOTE
When the engine is at a standstill and the electrical system
is switched on for a longer period (position I), the battery
discharges rapidly.
Switching on electrical system
Turn ignition key [1] to position I.
a
Electrical system is ON.
a
Functional control of warning and pilot lights
a
Diesel engine remains switched off.
Cold start assistance/preheating
The diesel engine needs to be preheated when it is cold.
This step can be omitted when the engine is at operating temperature.
Turn and hold the ignition key [1] in position II.
a
The cold start assistance [2] pilot lamp is lit.
a
The cold start assistance [2] pilot lamp goes out after a few seconds.
a
Ignition key turns back to position I after releasing.
a
The engine is ready to start.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RD24 and is the answer not in the manual?

Wacker Neuson RD24 Specifications

General IconGeneral
BrandWacker Neuson
ModelRD24
CategoryConstruction Equipment
LanguageEnglish

Related product manuals