Maintenance
Water sprinkling
BA RD24_RD27 en 04
161
1
1 3 2 4
Switch off diesel engine and remove ignition key.
Unscrew the filter head [1] from the water tank and remove it together
with the pressure spring [2] (be careful with the sealing rings [3] on
the filter head).
Pull the filter insert [4] from the water tank.
Clean filter insert and compression spring.
NOTE
Empty the water tank when the filter has been removed.
Place the filter insert [4] into the water tank.
Screw the filter head [1] with the seal rings [3] together with the
pressure spring [2] into the water tank.
NOTE
The filter insert must be replaced by a new one when it is
defective, worn out or cannot be cleaned.
For ordering, please contact the customer service.
4.08.04 Emptying and cleaning the water sprinkling system
3
1
2
Switch off diesel engine and remove ignition key.
Remove the valve insert [1] with membrane and the sprinkler nozzles
[2] with filter from the sprinkler nozzle casing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RD24 and is the answer not in the manual?

Wacker Neuson RD24 Specifications

General IconGeneral
BrandWacker Neuson
ModelRD24
CategoryConstruction Equipment
LanguageEnglish

Related product manuals