Diagnostic Code
192
BA RD24_RD27 en 04
Code No Component Possible cause
29 Generator exciter circuit Short-circuit, line break
30 Parking light Defective
31 Engine direction of travel monitoring Diesel engine running/run in reverse
5.04.02 Version with add-on equipment
Code No Component Possible cause
100 Driving light Open lines, short-circuit
102 Rotary beacon Open lines, short-circuit
103 Additive sprinkling pump Open lines, short-circuit
104 Drum edge lighting Open lines, short-circuit
105 Reverse light Open lines, short-circuit
106 Water sprinkling pump Open lines, short-circuit
107 Signal horn Open lines, short-circuit
110 Working spotlights left Open lines, short-circuit
111 Working spotlights right Open lines, short-circuit
112 Shut-down solenoid Open lines, short-circuit
113 Starting relay Open lines, short-circuit
114 Solenoid valve vibration rear Open lines, short-circuit
116 Alert buzzer Open lines, short-circuit
117 Drive pump Open lines, short-circuit
118 Flashing lights left Open lines, short-circuit
119 Parking light left Open lines, short-circuit
120 Solenoid valve KAG down Open lines, short-circuit
121 Solenoid valve KAG up Open lines, short-circuit
122 Parking brake Open lines, short-circuit
123 Solenoid valve vibration front Open lines, short-circuit
124 Reversing alarm Open lines, short-circuit
125 all-wheel lock Open lines, short-circuit
126 Parking light, right Open lines, short-circuit
127 Flashing lights right Open lines, short-circuit
128 Water sprinkling Internal plausibility error
129 Front or rear vibration solenoid valve Internal plausibility error
160 Machine CAN bus Internal plausibility error
161 Internal memory Internal plausibility error
164 Hydraulic oil pressure or temperature sensor Short-circuit, mechanical defect
165 Drive lever Implausible signal
166 Start conditions Implausible signal
600 HCM Defective

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RD24 and is the answer not in the manual?

Wacker Neuson RD24 Specifications

General IconGeneral
BrandWacker Neuson
ModelRD24
CategoryConstruction Equipment
LanguageEnglish

Related product manuals