4-39
IM DL350-17EN
Commands
4 
4.5  CALibrate Group
The commands in this group deal with calibration. You can perform the same operations and make the same settings 
and queries that you can by using Preparation > Calibration in the top menu.
:CALibrate?
Function  Queries all calibration settings.
Syntax
 :CALibrate?
:CALibrate[:EXECute]
Function  Executes calibration.
  This command is different from the common 
command *CAL? in that this command does 
not return the results when the calibration is 
completed.
Syntax
 :CALibrate[:EXECute]
:CALibrate:MODE
Function  Sets or queries the auto calibration mode.
Syntax
  CALibrate:MODE {AUTO|OFF}
 CALibrate:MODE?
Example
  :CALIBRATE:MODE AUTO
 :CALIBRATE:MODE?  
-> :CALIBRATE:MODE AUTO
:CALibrate:SBOCancel:CHANnel<x>[:
STATus] (Strain Balance & Offset 
Cancel)
Function  Sets or queries whether the specified channel 
is included in the balancing of all channels on 
strain modules or the DC offset canceling of all 
channels on voltage measurement modules.
Syntax
 :CALibrate:SBOCancel:CHANnel<x>[: 
STATus] {<Boolean>}
 :CALibrate:SBOCancel:CHANnel<x>[: 
STATus]?
  <x> = 1 to 4
Example
  :CALIBRATE:SBOCANCEL:CHANNEL1 ON
 :CALIBRATE:SBOCANCEL:CHANNEL1?  
-> :CALIBRATE:SBOCANCEL:CHANNEL1 1
Description  This command is valid when any of the following 
modules is installed.
 701270(STRAIN_NDIS), 
701271(STRAIN_DSUB), 720211 (HS100M12), 
720250 (HS10M12)
:CALibrate:SBOCancel:CHANnel<x1>:SCH
annel<x2>[:STATus] (Strain Balance & 
Offset Cancel)
Function  Sets or queries whether the specified 4-CH 
module’s channel is included in the balancing of 
all channels on strain modules or the DC offset 
canceling of all channels on voltage measurement 
modules.
Syntax
 :CALibrate:SBOCancel:CHANnel<x1>: 
SCHannel<x2>[:STATus] {<Boolean>}
 :CALibrate:SBOCancel:CHANnel<x1>: 
SCHannel<x2>[:STATus]?
  <x1> = 1 to 4
  <x2> = 1, 2
Example
 :CALIBRATE:SBOCANCEL:CHANNEL1:  
SCHANNEL1 ON
 :CALIBRATE:SBOCANCEL:CHANNEL1:  
SCHANNEL1?  
-> :CALIBRATE:SBOCANCEL:CHANNEL1:  
SCHANNEL1 1
Description  This command is valid when any of the following 
modules is installed.
 720254 (4CH 1M16)
:CALibrate:SBOCancel:EXECute (Strain 
Balance & Offset Cancel)
Function  Executes the strain balancing of all channels on 
strain modules or the DC offset canceling of all 
channels on voltage measurement modules.
Syntax
 :CALibrate:SBOCancel:EXECute
Example
 :CALIBRATE:SBOCANCEL:EXECUTE
Description  This command is valid when any of the following 
modules is installed.
 701270(STRAIN_NDIS), 
701271(STRAIN_DSUB), 720211 (HS100M12), 
720250 (HS10M12), 720254 (4CH 1M16)