JOHNSON CONTROLS
17
SECTION 2 – PRODUCT DESCRIPTION
FORM 150.67-NM2
ISSUE DATE: 01/31/2019
2
UNIT ON/OFF switch
The microprocessor control center is capable of dis-
playing the following:
Return and leaving liquid temperature
Low leaving liquid temperature cutout setting
Low ambient temperature cutout setting
Outdoor air temperature
English or Metric data
Suction pressure cutout setting
Each system suction pressure
Discharge pressure (optional)
Liquid Temperature Reset via a YORK ISN DDC
or Building Automation System (by others) via:
a pulse width modulated (PWM) input as
standard.
a 4-20 milliamp or 0 -10 VDC input with the
optional B.A.S. interface option.
Anti-recycle timer status for each system
Anti-coincident system start timer condition
Compressor run status
No cooling load condition
Day, date and time
Daily start/stop times
Holiday status
Automatic or manual system lead/lag control
Lead system denition
Compressor starts and operating hours (each com-
pressor)
Status of hot gas valves, evaporator heater and fan
operation
Run permissive status
Number of compressors running
Liquid solenoid valve status
Load and unload timer status
Water pump status
* Intensity of Protection European Standard
** International Electrotechnical Commission
Provisions are included for: pumpdown at shutdown;
optional remote chilled water temperature reset and
two steps of demand load limiting from an external
building automation system. Unit alarm contacts are
standard.
The operating program is stored in non-volatile mem-
ory (EPROM) to eliminate chiller failure due to AC
powered failure/battery discharge. Programmed set-
points are retained in lithium battery-backed RTC
memory for 5 years minimum.
POWER PANEL
Each panel contains:
Compressor power terminals
Compressor motor starting contactors per l.E.C.**
Control power terminals to accept incoming for
115-1-60 control power
Fan contactors and overload current protection
The power wiring is routed through liquid-tight con-
duit to the compressors and fans.
ACCESSORIES AND OPTIONS
Power Options
COMPRESSOR POWER CONNECTION – Sin-
gle-point (YCAL0019-0066) terminal block connec-
tion is provided as standard. The following power con-
nections are available as options. (See electrical data
for specific voltage and options availability) (Factory-
Mounted).
SINGLE-POINT SUPPLY TERMINAL BLOCK
(standard on YCAL0019 – 0066 models) Includes en-
closure, terminal-block and interconnecting wiring to
the compressors. Separate external protection must be
supplied, by others, in the incoming compressor-power
wiring. (Do not include this option if either the Single-
Point Non-fused Disconnect Switch or Single-Point
Circuit Breaker options have been included).
SINGLE-POINT NON-FUSED DISCONNECT
SWITCH – Unit-mounted disconnect switch with
external, lockable handle (in compliance with Article
440-14 of N.E.C.), can be supplied to isolate the unit
power voltage for servicing. Separate external fusing
must be supplied, by others in the power wiring, which
must comply with the National Electrical Code and/or
local codes.

Table of Contents

Other manuals for York YCAL0043

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York YCAL0043 and is the answer not in the manual?

York YCAL0043 Specifications

General IconGeneral
BrandYork
ModelYCAL0043
CategoryChiller
LanguageEnglish

Related product manuals