5.3.6.2 PTZ Set
Click [Main MenuDevicePTZ] to enter into the below window shown as Picture 5-37
Picture 5-41
5.3.6.3 Alarm Set
Click [Main MenuDeviceAlarm] to enter into the below window shown as Picture 5-38. Now you
can perform alarm set based on different status. Details please refer to List 5-1.
Picture 5-42
Latch: you can set how long the buzzer will sound when external sensor alarm is detected (10s, 20, 40s,
60s);
Show Message: You can set show message on the screen when sensor alarm is detected.
Buzzer time: you can set how long the buzzer will sound when motion is detected (Off, 10s, 20,
40s, 60s);
Send Email:allows you set the alarm images is issued to a specified email or not.
Full screen Alarm: The function is defaulted to “On". When the motion detection or external
alarm is triggered, the corresponding channel will be switched to the full screen mode.
Record Delay: you can set how long alarm record will last when alarm ends (30s, 1minute,
2minute,5minute);
Copy: allow you copy all the setting of one channel to other ones.
Alarm Type Function
Video Loss
Sends alarm when DVR can’t receive video signal (such as camera damage, cable broken or
damaged or power supply malfunction).
Motion Detection
When an object moves into motion detection area, alarm will be triggered. You can adjust sensitivity
level to suit the needs of your actual application environment.
I/O Status
System can convert alarm signal triggered by external sensor into signal identified by system.
You could select the channel you desire to control and set
PTZ protocol (Pelco-D or Pelco-P), Baud Rate (1200,
2400, 4800, 9600), Data bit (8, 7, 6, 5), Stop bit (1, 2),
Parity Check (None, Odd, Even, Mark, Space), Address
Code and Cruise status respectively. Please note the PTZ
device can be activated only when a channel in connection
with the PTZ camera is selected.
No: allow you select one desired channel
I/O Status: allows you select the three options – NO (Normal
Open), NC (Normal Close) and OFF. Set to “Normal Open”,
I/O status Alarm will be activated while sensor is ON; set to
“Normal Close”, I/O status alarm will be activated while
sensor is OFF; set to “OFF”, I/O status alarm will not be
triggered.
Alarm out: allow you connect external alarm sensor.