EtherNet/IP – Communication protocol 239
8 Con-
sumed
Connec-
tion size
Get Maximum number of bytes
received across this connection
UINT16
9 Expected
Packet
Rate
Get, Set Defines the timing associated
with this connection in
milliseconds. A value of 0
deactivates the associated
timers.
UINT16
12 Watchdog
Timeout
Action
Get, Set Defines how to handle
Inactivity/Watchdog timeouts.
UINT8
13 Produced
Connec-
tion Path
Length
Get Number of bytes in the
produced_connection_path
length attribute
UINT16
14 Produced
Connec-
tion Path
Get Application object producing
data on this connection
Array of
UINT8
15 Con-
sumed
Connec-
tion Path
Length
Get Number of bytes in the
consumed_connection_path
length attribute
UINT16
16 Con-
sumed
Connec-
tion Path
Get Specifies the application
object(s) that are to receive the
data consumed by this
connection object.
Array of
UINT8
17 Produc-
tion Inhibit
Time
Get Defines the minimum time
between new data production in
milliseconds.
UINT16
# Attribute
name
Services Description Data
type

Table of Contents

Other manuals for ABB FENA-21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB FENA-21 and is the answer not in the manual?

ABB FENA-21 Specifications

General IconGeneral
BrandABB
ModelFENA-21
CategoryAdapter
LanguageEnglish

Related product manuals