- 86 -
000413BG
8 - Maintenance
Routine maintenance
Scheduled maintenance operations are not mandatory, but are recom-
mended to preserve the efciency of the PV plant.
We recommend that maintenance operations be carried out by qualied personnel or by the
personnel of ABB (as set forth in a maintenance contract).
The periodicity of the maintenance operations may vary in accordance with local environmen-
tal conditions and the installation
Table: routine maintenance
Annual visual inspection
Check that the inverter is operating correctly, and that no fault alarms are present
• Ensure all the labels and safety symbols are visible
Test the integrity of the cables, connectors, and plugs external to the inverter
Check that the environmental conditions have not changed drastically since
the installation of the system
Annual operations • Check that cable glands and connection block screws are tight
• Check that the wiring box cover is properly closed
• If no monitoring system is present, check the history log of alarms and errors
using the instructions given in the manual in order to look for recent malfunction
warnings
Annual cleaning Clean the equipment; in particular the bottom grille of the wiring box and the
heat sink
Troubleshooting
Follow the table shown in the following paragraph in order to understand
and resolve warning (Wxxx) and error (Exxx) messages displayed by the
inverter
The operations carried out on the inverter in order to identify and resolve malfunctions may be
carried out only by the organization that carried out the installation or by qualied personnel
Alarm Messages
The equipment is able to indicate errors/warnings on the display only if
the input voltage is higher than the Vdcmin voltage (POWER LED ash-
ing or on; see operation chapter).
The messages and their codes are indicated on the display.
The following table gives the complete list of errors/warnings relating to string inverters. Some
error/warning codes may not be used depending on the inverter model installed.

Table of Contents

Other manuals for ABB PVI-6.0-TL-OUTD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PVI-6.0-TL-OUTD and is the answer not in the manual?

ABB PVI-6.0-TL-OUTD Specifications

General IconGeneral
BrandABB
ModelPVI-6.0-TL-OUTD
CategoryInverter
LanguageEnglish

Related product manuals