EasyManuals Logo
Home>ABB>Computer Hardware>TPU2000

ABB TPU2000 User Manual

ABB TPU2000
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
TPU2000/2000R Modbus/Modbus Plus/ Modbus TCP/IP Automation Guide
92
Register
Address
Item Scale
Factor
Description
40280 % Fifth Harmonic-B Winding 1 2 Unsigned High Order Byte LSB
40280 % Fifth Harmonic-C Winding 1 2 Unsigned Low Order Byte MSB
40281 % All Harmonic-A Winding 1 2 Unsigned High Order Byte LSB
40281 % All Harmonic-B Winding 1 2 Unsigned Low Order Byte MSB
40282 % All Harmonic-C Winding 1 2 Unsigned High Order Byte LSB
40282 % Second Harmonic-A Winding 2 2 Unsigned Low Order Byte MSB
40283 % Second Harmonic-B Winding 2 2 Unsigned High Order Byte LSB
40283 % Second Harmonic-C Winding 2 2 Unsigned Low Order Byte MSB
40284 % Fifth Harmonic-A Winding 2 2 Unsigned High Order Byte LSB
40284 % Fifth Harmonic-B Winding 2 2 Unsigned Low Order Byte MSB
40285 % Fifth Harmonic-C Winding 2 2 Unsigned High Order Byte LSB
40285 % All Harmonic-A Winding 2 2 Unsigned Low Order Byte MSB
40286 % All Harmonic-B Winding 2 2 Unsigned High Order Byte LSB
40286 % All Harmonic-C Winding 2 2 Unsigned Low Order Byte MSB
40287 % Second Harmonic-A Winding 3 2 Unsigned High Order Byte LSB
40287 % Second Harmonic-B Winding 3 2 Unsigned Low Order Byte MSB
40288 % Second Harmonic-C Winding 3 2 Unsigned High Order Byte LSB
40288 % Fifth Harmonic-A Winding 3 2 Unsigned Low Order Byte MSB
40289 % Fifth Harmonic-B Winding 3 2 Unsigned High Order Byte LSB
40289 % Fifth Harmonic-C Winding 3 2 Unsigned Low Order Byte MSB
40290 % All Harmonic-A Winding 3 2 Unsigned High Order Byte LSB
40290 % All Harmonic-B Winding 3 2 Unsigned Low Order Byte MSB
40291 % All Harmonic-C Winding 3 2 Unsigned High Order Byte LSB
40291 Current Tap Scale Winding 1 10 Unsigned Low Order Byte MSB
40292 Current Tap Scale Winding 2 10 Unsigned High Order Byte LSB
40292 Current Tap Scale Winding 3 10 Unsigned Low Order Byte MSB
Load Current and Angular Values (63 Registers Defined TPU 2 Winding – 66 Registers
Defined TPU 3 Winding)
Load Currents for the windings are reported in Registers 40385 though 40447 for a Two Winding
TPU2000/2000R. If the Modbus card is inserted in a 3 Winding Unit, the status is reported in 40385 through
40450. Ground Current Angles and Magnitudes were added in version X.XX flash executives and version 1.80
Modbus chipsets.
Table 5-20. Demand Metering Modbus Address Map Definition
Register
Address
Item Description
40385 Load Current A Winding 1 Unsigned 32 Bit High Order Word MSW
40386 Load Current A Winding 1 Unsigned 32 Bit Low Order Word LSW
40387 Load Current B Winding 1 Unsigned 32 Bit High Order Word MSW
40388 Load Current B Winding 1 Unsigned 32 Bit Low Order Word LSW
40389 Load Current C Winding 1 Unsigned 32 Bit High Order Word MSW
40390 Load Current C Winding 1 Unsigned 32 Bit Low Order Word LSW
40391 Load Current N Winding 1 Unsigned 32 Bit High Order Word MSW
40392 Load Current N Winding 1 Unsigned 32 Bit Low Order Word LSW
40393 Load Current A Winding 2 Unsigned 32 Bit High Order Word MSW
40394 Load Current A Winding 2 Unsigned 32 Bit Low Order Word LSW
40395 Load Current B Winding 2 Unsigned 32 Bit High Order Word MSW
40396 Load Current B Winding 2 Unsigned 32 Bit Low Order Word LSW
40397 Load Current C Winding 2 Unsigned 32 Bit High Order Word MSW
40398 Load Current C Winding 2 Unsigned 32 Bit Low Order Word LSW