TPU2000/2000R Modbus/Modbus Plus/ Modbus TCP/IP Automation Guide
62
Register
Address
Item Description
3 00162 OCA-3 Winding 3 Overcurrent Alarm Energized
3 00163 PWatt3 Winding 3 Positive 3 Phase kWatt Alarm Energized
3 00164 OCA Gnd Ground Overcurrent Alarm Energized
3 00165 Reserved Reserved
3 00166 Reserved Reserved
3 00167 Reserved Reserved
3 00168 Reserved Reserved
3 00169 Reserved Reserved
3 00170 Reserved Reserved
3 00171 Reserved Reserved
3 00172 Reserved Reserved
3 00173 Reserved Reserved
3 00174 Reserved Reserved
3 00175 Reserved Reserved
3 00176 Reserved Reserved
3= 3 Winding TPU Only
(L)= Latched or Seal In Point
Physical Output Block (Two Bit Data with Momentary Change Detection): Not available
on TPU2000
The TPU2000R allows for momentary bit change detect for all physical outputs on the protective device. The
physical output devices. The status bit will reflect the same status as that of 00257 through 00272. The
momentary bit shall detect a status change between reads of the element’s data. As always, the bits must be
read in pairs for accurate reporting of the element status. Table 5-4 lists the definitions of each defined 0X
address.
Table 5-4. Modbus Physical Output Momentary Change Detect Address Allocation
Discrete
Address
Item Description
01025 Spare Status Reserved
01026 Spare Momentary Reserved
01027 Spare Status Reserved
01028 Spare Momentary Reserved
01029 Spare Status Reserved
01030 Spare Momentary Reserved
01031 Spare Status Reserved
01032 Spare Momentary Reserved
01033 Spare Status Reserved
01034 Spare Momentary Reserved
01035 Spare Status Reserved
01036 Spare Momentary Reserved
01037 Spare Status Reserved
01038 Spare Momentary Reserved
01039 Spare Status Reserved
01040 Spare Momentary Reserved
01041 OUT 7 Physical Output Contact 7
01042 OUT 7 Physical Output Contact 7 Change Detect Between Scans
01043 OUT 6 Physical Output Contact 6
01044 OUT 6 Physical Output Contact 6 Change Detect Between Scans
01045 OUT 5 Physical Output Contact 5
01046 OUT 5 Physical Output Contact 5 Change Detect Between Scans
01047 OUT 4 Physical Output Contact 4