TPU2000/2000R Modbus/Modbus Plus/ Modbus TCP/IP Automation Guide
208
(Windings 1 and 2) 0<=Range <=330 : /30
61418 Winding 1 CT Configuration
U
U
n
n
s
s
i
i
g
g
n
n
e
e
d
d
I
I
n
n
t
t
e
e
g
g
e
e
r
r
1
1
6
6
B
B
i
i
t
t
s
s
0 = Wye
61419 Winding 1 CT Configuration
U
U
n
n
s
s
i
i
g
g
n
n
e
e
d
d
I
I
n
n
t
t
e
e
g
g
e
e
r
r
1
1
6
6
B
B
i
i
t
t
s
s
0 = Wye
61420 Phase Rotation Unsigned Integer
0 = ABC Rotation : 1 = ACB Rotation
61421 ALT 1 Setting Enable Unsigned Integer 16 Bits
1 = Enabled : 0 = Disabled
61422 ALT 1 Setting Enable Unsigned Integer 16 Bits
1 = Enabled : 0 = Disabled
61423 Trip Failure Mode Unsigned Integer 16 Bits
0 = Differential Trip
1 = Overcurrent Alarm
2 = Differential and Overcurrent Trip Alarm
61424 Trip Failure Time Unsigned Integer
5<=Range<=60 Seconds
61425 Trip Fail Dropout % Pickup Unsigned Integer
5<=Range<=90
61426 Configuration Flag
Bit 0 = OC Protect Mode
Bit 1 = Reset Mode
Bit 2 = Reserved
Bit 3 =Target Display Mode
Bit 4 = Local Edit
Bit 5 = Remote Edit
Bit 6 = Whr/VarHr Mtr Mode
Bit 7 = LCD light
Bit 8 = Cross Block Mode
Bit 9 = Reserved
Bit 10 = Reserved
Bit 11 = Reserved
Bit 12 = Reserved
Bit 13 = Reserved
Bit 14 = Reserved
Bit 15 = Reserved
Unsigned Integer 16 Bits
0 = Fundamental 1= RMS (lsb) Leftmost Bit
0 = Instant 1 = Delayed
Reserved
0 = Last 1 = All
0 = Disabled 1 = Enabled
0 = Disabled 1 = Enabled
0 = Kwh 1 = MwHr
0 =Timer 1= On
0 = Disabled 1= Enabled
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved (msb) Rightmost Bit
61427 Unit Name ASCII – 2 Characters Leftmost Digits
61428 Unit Name ASCII – 2 Characters Digits
61429 Unit Name ASCII – 2 Characters Digits
61430 Unit Name ASCII – 2 Characters Digits
61431 Unit Name ASCII – 2 Characters Digits
61432 Unit Name ASCII – 2 Characters Digits
61433 Unit Name ASCII – 2 Characters Digits
61434 Unit Name ASCII – 2 Characters Digits
61435 Unit Name ASCII – 2 Characters Rightmost Digits
61436 Transformer Configuration Unsigned Integer 16 Bits
0 = Y1-Y2-D3
1 = Y1-D2-Y3
2 = D1-Y2-Y3
3 = Y1-D2-D3
4 = D1-D2-Y3
5 = D1-Y2-D3
6 = D1-D2—D3
7 = Y1-Y2-Y3
61437 Time Demand Constant Unsigned Integer 16 Bits
0 = 5
1 = 15
2 = 30