102
Chapter 3 Features and Functions
Frequency Sweep
3
Sweep Mode
You can sweep with either linear or logarithmic spacing.
For a
linear
sweep, the function generator varies the output frequency
in a linear
fashion during the sweep. For a logarithmic sweep, the function
generator varies the output frequency in a logarithmic fashion.
Sweep mode: Linear or Logarithmic. The default is Linear.
Front-Panel Operation: After enabling sweeps, press the Linear
softkey again to toggle between the linear or log mode.
Remote Interface Operation:
SWEep:SPACing {LINear|LOGarithmic}
Sweep Time
The sweep time specifies the number of seconds required to sweep from
the start frequency to the stop frequency.
The number of discrete
frequency points in the sweep is automatically
calculated by the function
generator and is based on the sweep time you select.
Sweep time: 1 ms to 500 seconds. The default is 1 second.
Front-Panel Operation: After enabling sweeps, press the Sweep Time
softkey. Then use the knob or numeric keypad to enter the desired
sweep time.
Remote Interface Operation:
SWEep:TIME {<seconds>|MINimum|MAXimum}

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 33220A and is the answer not in the manual?

Agilent Technologies 33220A Specifications

General IconGeneral
BrandAgilent Technologies
Model33220A
CategoryInverter
LanguageEnglish

Related product manuals