87
Chapter 3 Features and Functions
Phase Modulation (PM)
3
Modulating Waveform Shape
The function generator will accept an internal or external modulation
source for PM.
Modulating waveform shape (internal source): Sine, Square, Ramp,
Negative Ramp, Triangle, Noise, or Arb waveform.
The default is Sine.
Square has 50% duty cycle.
Ramp has 100% symmetry.
Triangle has 50% symmetry.
Negative ramp has 0% symmetry.
You can use noise as the modulating waveshape, but you cannot use
noise, pulse, or dc as the carrier waveform.
If you select an arbitrary waveform as the
modulating
waveshape
,
the waveform is automatically limited to 4K points. Extra waveform
points are removed using decimation.
Front-Panel Operation: After enabling PM, press the Shape softkey.
Remote Interface Operation:
PM:INTernal:FUNCtion {SINusoid|SQUare|RAMP|NRAMp|
TRIangle|NOISe|USER}
Modulating Waveform Frequency
The function generator will accept an internal or external modulation
source for PM.
Modulating frequency (internal source): 2 mHz to 20 kHz.
The default is 10 Hz
.
Front-Panel Operation
: After enabling PM, press the
PM Freq
softkey.
Remote Interface Operation
:
PM:INTernal:FREQuency {<
frequency
>|MINimum|MAXimum}

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 33220A and is the answer not in the manual?

Agilent Technologies 33220A Specifications

General IconGeneral
BrandAgilent Technologies
Model33220A
CategoryInverter
LanguageEnglish

Related product manuals